Fully automated ELISA processor (BIOBASE2000)
BIOBASE2000 Elisa Processors is fully automated Four-plate ELISA processing system, capable of sampling, incubation, washing and data processing. It is complete solution for your IVD ELISA assays. The system combines a high precision pipetting unit with stable incubators and efficiency washers and photometer unit.
Features:
-
1 Robotic hand.
-
2 Pipetting probe, 1ul stepping (1000ul volumes).
-
Total 25 racks, arbitrary rack can be defined as sample or reagent on the software.
-
4 units 96 well microplates (pipetting,incubator,reading).
-
1 unit independent washer & reader( two 8 nozzle manifolds).
Model
|
BIOBASE2000
|
Sample pipetting unit
|
Sample rack
|
24 sample tubes/rack, at most 25 racks
|
Primary sample tubes
|
11.5-13mm
|
Pipetting
|
8ul~1000ul, (10ul) CV<5%
|
Time to dispense
|
15 minutes (typical)^100ul of 96 samples to plate
from sample tubes or dilution tubes.
|
Dispensing system
|
1 aspirating-dispensing probe with X-Y-Z movement;dilution system
with a syringe of 1000ul, continuous flow washing station.
|
Reagent pipetting unit
|
Reagent racks
|
2 reagent tanks(60ml)/ rack, at most 25 racks
|
QC racks
|
24 positions/QC rack, at most 25 racks
|
Pipetting
|
8ul~1000ul,1ul stepping,
|
pipetting precision
|
(100ul )CV≤0.5%
|
Time to dispense
|
2 minutes(typical)^100ul of 96 reagents to plate from reagent bottle
|
Washing unit
|
Programmable
|
Yes(options & parameters)
|
Wash containers
|
4 wash buffers at 2.0L, with level-sensing
|
Waste containers
|
10L with waste full sensor
|
Washing system
|
two 8 nozzle manifolds, one to dispense and the other one to aspirate;
|
Washing residual
|
<2μl
|
Reading unit
|
Reading system
|
8 independent photometric channels with mono
and bichromatic reading capability
|
Photometric range
|
0.000 ~3.000 OD
|
Spectral range
|
400-700nm
|
Optical filters
|
2 precision filters (450and 630nm); 2 more on request
(4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)
|
Reading inaccuracy
|
inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD
|
Incubation unit
|
Incubators
|
4 independent units
|
Programmable
|
Yes
|
Temperature range
|
RT to 45 °C
|
Temperature accuracy
|
±0.5?
|
Temperature stability
|
±0.5?
|
Software unit
|
Software system
|
Windows XP or Windows 7 or above, LIS system available,
realize two-way data communications
|
Function application
|
work list set up, patient reports and result filing; calibration curve,
storage for each carried out test
|
Data reduction
|
cut-off (qualitative)
|
Physical Specification
|
Power Supply
|
AC220V+ 10%,50/60Hz,450W
|
Instrument Dimension
|
110*72*70cm (L*W*H)
|
Instrument Weight
|
100kg
|
Package Dimension
|
138*91*98cm(L*W*H)
|
Total Weight
|
150kg
|